Loading...
2001-061RESOLUTION NO. 2001-61 A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF AVENTURA, FLORIDA APPROVING AND AUTHORIZING THE CITY MANAGER TO EXECUTE AND OTHERWISE ENTER INTO THE A'I-rACHED CHANGE ORDER FOR THE AVENTURA GOVERNMENT CENTER, BY AND BETWEEN THE CITY AND JAMES A. CUMMINGS, INC; AUTHORIZING THE CITY MANAGER TO DO ALL THINGS NECESSARY TO CARRY OUT THE AIMS OF THIS RESOLUTION; AND PROVIDING AN EFFECTIVE DATE. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COMMISSION OF THE CITY OF AVENTURA, FLORIDA, THAT: Section 1. The City Manager is hereby authorized to execute and otherwise enter into Change Order Number 9 for the Aventura Government Center, by and between the City and James A. Cummings, Inc., attached hereto and incorporated herein as specifically as if set forth at length herein. Said Change Order amount is $97,956.00. Section 2. The City Manager is hereby authorized to do all things necessary to carry out the aims of this Resolution. Section3. This Resolution shall become effective immediately upon its adoption. The foregoing Resolution was offered by Commissioner Rogers-Libert, who moved its adoption. The motion was seconded by Commissioner Holzberg, and upon being put to a vote, the vote was as follows: Commissioner Arthur Berger yes Commissioner Jay R. Beskin yes Commissioner Manny Grossman yes Commissioner Harry Holzberg yes Commissioner Patricia Rogers-Libert yes Vice Mayor Ken Cohen yes Mayor Jeffrey M. Perlow yes Resolution No. 2001-6__~ Page 2 PASSED AND ADOPTED this 4th day of September, 2001. ~Y PE"'RLOW, MAYOR ATTEST: APPROVED AS TO LEGAL SUFFICIENCY: CITY ATTORNEY EHA GE OI~)ER Page 1 of 3 PROJECT: Aventura Government Center, Police Facility CHANGE ORDER NUMBER: 09 19200 West Country Club Drive DATE: 0~-31-0~ Aventura, FL 33180 TO CONTRACTOR: James A. Cummin~s. lnc. 3575NW53~reet Fo~Laude~ale, FL 33309 ARCHITECT'S PROJECT NO: 97-20 CONTRACT DATE: 12-tS-98 The Contract is chan~ed as follows: Owner Change Order #09 Not valid until siQned bv the Owner. Architect and Contractor 1. Provide electrical grounding of the Computer Access Flooring at the 3rd Floor in accordance with Request for Change Order #0213, Revision #1 dated April 12, 200l ................................................................ ADD: $14,704.00 2. Provide an additional finish partition end door and relocate existing door at the Dh'eetor o£Community Sevices Room #409 in accordance with Request for Change Order #0265, Revision #1 dated July 09, 2001 .......................... ..................................................................................................................................................... ADD: $ 3,156.00 3. Provide two (2) each additional duct detectors for stairwell pressurization fan numbers SF-I and SF-2 in accordance with Request for Change Order #0275 dated July 12, 2001 ........................................ ADD: $ 2,721.00 4. Revise the light fixtures in Shell Room #334 to type "B" fixtures and modi~ the fire alarm wiring as required to add anacoustical ceiling to this space in accordance with Request for Change Order #276 dated June 19, 2001 ............................................................................................................................................ ADD: $ 1,297.00 5. Provide grounding to the Iow voltage cabinets in accordance with Request for Change Order #0278 dated July 12,2001 ..................................................................................................................................... ADD: $ 4,525.00 6. Add three (3) each additional flouresceat lights at the Parking Garage as required by Miami-Dade Fire Rescue in accordance with Request for Change Order #0279 dated May 31, 2001 .................................... ADD: $ 1,403.00 7. Provide Additional Exhaust Fans g# end #9 in Elevator Machine Rooms #109 and #162 in accordance with Request for Change Order #0294 dated May 23, 2001 ................................................................... ADD: $ 6,712.00 $. Provide additional Fire Lane Striping and "No Parking Fire Lane" Signs as required by Miami-Dade Fire Rescue in accordance with Request for Change Order #0307 dated June 07, 2001 .................................... ADD: $ 3,202.00 9. Provide sixty (60) each flor mounted door stop holders throughout the building in accordance with Request for Change Order #0310 dated June 19, 2001 .................................................................................... ADD: $ 2,316.00 10. Provide four (4) each Static Pressure Sensors at the Return and Supply Air Ducts in accordance with Request for Change Order #0313 dated June 14, 2001 ............................................................................... ADD: $ 4,684.00 Prolog C:~PROLOC,4~PROJECTS~AVENTURA, PMD CHANGE Page 2 of 3 PROJECT: Aventura Government Center, Police FacilitY CHANGE ORDER NUMBER: 09 19200 West Country Club Drive DATE: 08-31-0'i Aventura, FL 33180 TO CONTRACTOR: James A. Cummin~3s, Inc. 3575 NW 53rd Street Foal Lauderdale, FL 33309 ARCHITECT'S PROJECT NO: 97-20 CONTRACT DATE: 1245-98 The Contract is chan;led as follows: Owner Change Order #09 Not valid until si(3ned bv the Owner, Architect and Contractor 11. Provide a gypsum wallboard alcove and relocate the double doors leading into Loading and Receiving Room #169 as required by Miami-Dada Fire Rescue in accordance with Request for Change Order #0316, Revision 1 dated August 02, 2001 .................................................................................................................. ADD: $ 4,386.00 12. Furnish and Install Panels HP-1/LP-I and Transformer//4 at the 1st Floor Electrical Room in accordance with Request for Change Order #0319 dated June 19, 2001 ................................................................. ADD: $ 15,902.00 13. Furnish and Install Panel LP-5 and Transformer #5 at the Tower Roof Electrical Room in accordance with Request for Change Order #0320 dated June 20, 2001 .................................................................. ADD: $11,369.00 14. Revise treads at Stair #2 to granite treads with zinc strip inserts in accordance with Request for Change Order #0322 dated June 21,2001 ........................................................................................................... ADD: $ 21,208.00 15. Provide three (3) each Thumb Turn Cylinders at Terrace Doors #331 A, 331B and 5 I0A in accordance with Request for Change Order #0333 dated July 24, 2001 .................................................................. ADD: $ 59.00 16. Provide three (3) each additional door closers at door numbers 149A, 205A, and 321A in accordance with Request for Change Order #0334 dated July 24, 2001 ................................................................. ADD: $ 312.00 17. It is understood and agreed that the Contract Time will be increased to complete this additional Work. At this time the duration &the time extension required can not be determined. Once the Work is complete, a time extension for this Work will be included in a subsequent Owner Change Order. Prolog C:q3ROLOC,4~PROJECTS~AVENTURA. PMD JHAl GE . OI, tl)ER Page 3 of 3 PROJECT: Aventura Government Center, Police Facility CHANGE ORDER NUMBER: 09 19200 West Country Club Drive DATE: 08-31-01 Aventura, FL 33180 TO CONTRACTOR: James A. Cummings, Inc. 3575 NW 53rd Street Fort Lauderdale, FL 33309 ARCHITECT'S PROJECT NO: 97-20 CONTRACT DATE: ¶2-¶~98 The Contract is chan~led as follows: Owner Change Order ~09 Not valid until si(~ned bv the Owner, Architect and Contractor The odainal (~ (Guaranteed Ma~mum Price) was ............................................................................................. Ne~ chanqe by previously authorized Chan~e Orders ......................................................................................................... The ~la:m"~x'~) (Guaranteed Mmdmum Price) pdor to this Charge Order was ............................................................... The K:~) (Guaranteed Maximum Pdce) will be (increased) ~ ~P..~R: (~CtX~[~!~ by this Chan~le Order in the amount of ...................................................................................................... The new ( _ _O~I~X~0m~I:(G u aranteed Maximum Pdce) includin~ this Chanfle Order The Contract time wfl be ( ;¢,cr ear, ecl) (II~,~SI~'~]I[1~ The date of Substantial CornD,~*Jon as of the date of this Chan~e Order ther~ore is ............................................................ 13.028.94600 (154.305.00) 12.874.641.00 97.95600 ¶ 2,972,597.00 See Item #17 See Item #17 NOTE: This summary does not reflect chanoes in the Contract Sum, Contract Time or Guaranteed Maximum Pdce which have been authorized by Construction Chan~e Directive. Michael A. Shift & Associates, Inc. ARCHITECT 1103 East Las Olas Boule, ard. Suite 200 Address Fo~t Lauderdale, FL 33301 BY Ress Saleqe~ James A. Cummings, Inc. CONTRACTOR 3575 NW 53rd Streat Fort Lauderdale, FL 33309 C~dAventu~ OWNER 2999NE191Stree~.Su~500 Addr~s A,~tum. FL~l~ BY Edc M. Scmka ~ SIGNATURE ~. DATE ~/~/~) i Prolog C :~PROLOC~PROJ E CTS..YE NTU P,A. p MD