Loading...
3301 NE 183 STU.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE Fede, a, Emergency Management Agency Aventura - 120676 National Flood Insurance Program Important: Read the instructions on pages 1 -8. 08 -0216 FR 991 -411 SECTION A- PROPERTY INFORMATION Al. Building Owner's Name B7. FIRM Panel PENINSULA II DEVELOPMENT, INC. B9. Base Flood Elevation(s) (Zone A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. ' 1 N.E. 183 Street (Tower) Effective /Revised Date i OMB No. 1660 -0008 Expires February 28. 2009 For Insurance Company Use: City State ZIP Code Aventura FL 33160 _ A3. Property ENT (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Portion of Tract t C, Q PENINSULA, Plat Book 147, Page 67, Miami -Dade County, Florida. A4. Building Use (e.g., Residential, Non - Residential, Addition, Accessory, etc.) Residential �,/- A5. Latitude /Longitude: Lat. 25 °56'47.2" Long. -80 °08'11.4" Horizon Iq 2 v, ( U/?` ` 3 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. "1 J AT Building Diagram Number 1 A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an a) Square footage of crawl space or enclosure(s) 0 sq ft a) Square footage of �y,r b) No. of permanent flood openings in the crawl space or b) No. of permanent f gs m the attached garage enclosure(s) walls within 1.0 foot above adjacent grade 0 walls within 1.0 foot above adjacent grade 0 c) Total net area of Flood openings in A8.b 0 sq in c) Total net area of flood openings in A9.b 0 sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 'l ' '" Community Name 8 Community Number B2. County Name 63. State Aventura - 120676 1 Miami -Dade FL B4. Map /Panel Number B5. Suffix 86. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone 9.5 ® feet Date Effective /Revised Date Zones) AO, use base flood depth) 12025CO084 J 7/17/95 3/2/94 AE 9 810. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe)_ 611. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ®No Designation Date _ ❑ CBRS ❑ OPA _ SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction' ® Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, AR/AE, ARlA1 -A30, AR/AH, AR/AO. Complete Items C2.a -g below according to the building diagram specified in Item AT Benchmark Utilized MDCBMX -18, at 6.29 Vertical Datum NGVD 1929 Conversion /Comments None a) Top of bottom floor (including basement, crawl space, or enclosure floor) - b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment in Comments) f) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) Check the measurement used. 9.5. ® feet ❑ meters (Puerto Rico only) 19.3 ® feet ❑ meters (Puerto Rico only) N/A._ ❑ feet ❑ meters (Puerto Rico only) 7.4 ® feet ❑ meters (Puerto Rico only) 9.5 ® feet ❑ meters (Puerto Rico only) 7.7 ® feet ❑ meters (Puerto Rico only) 16.3 ® feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elev information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ® Check here if comments are provided on back of form. Leavy, ilanio C. Fortin, PSM Florida Reg. No. LS2853 FEMA Form 81 -31, February 2006 See reverse side for continuation. Replaces all previous editions 3301 N.E. 183 Street i City Aventura State FL ,iuoing Apt., Unit, Suite, 3r) IP Code 33160 SECTION D - SURVI or and Section ENGINEER, OR ARCHITECT CERTIFICATION ror Insurance Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. r Comments Item C2e: Transformer vault room in non - attached garage at elev. + 7,66. The Elevator ipment room in the garage has an elevation of 7.5 feet. Use: SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE (WITHOIUTttBFE)ents For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR -F request, complete Sections A, B, and C. For Items Et -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. Ell. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters b) Top of bottom floor (including basement, crawl space, or enclosure) is _._ ❑ feet ❑ above or ❑below the HAG. ❑ meters El above or ❑ below the LAG. E2. For Building Diagrams 6 -8 with permanent flood openings provided in Section A Items 8 and /or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is __ ❑ feet ❑ meters ❑ above or ❑below the HAG. E5, Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. L SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CFRTIFtrATInM The property owner or owner's authorized representative who completes Sections A, B. and E for Zone A (without a FEMA- issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name City Date ZIP SECTION G - COMMUNITY INFORMATION (OPTIONAL) 70ffi l who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), levation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. nformation in Section C was taken from other documenta tion that has been signed and sealed by a licensed surveyor, engineer, or architect who thorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) munity official completed Section E for a building located in Zone A (without a FEMA- issued or community- issued BFE) or Zone AO. ollowing information (Items G4. -G9.) is provided for community floodplain management purposes. Permit G5. Date Permit Of This permit has been issued for: ❑ New Construction ❑ Substantial Improvement Elevation of as -built lowest floor (including basement) of the building: —_ ❑ feet ❑ meters (PR) Datum BFE or (in Zone AO) depth of flooding at the building site: _ _ ❑ feet ❑ meters (PR) Datum Ime ❑ Check here if attachments EMA Form 81 -31, February 2006 Replaces all previous editions Building Photographs See Instructions for Item A6. E ng Street Address (including Apt, Unit, Suite, 33u i N.E. 183 Street State ZIP NMI If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, 'Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. pppfi 2: R Pictures shown hereon were taken on June 22, 2007, Left Side View Left Side View Front View (Lobby Level) Rear View (Lobby level) November 27, 2007 Via Facsimile (954) 363 -3900 and Regular U.S. Mail Ms. Rebeca Kanakis Aventura Land Holding II Ltd. 321 East Hillsboro Boulevard Deerfield Beach, FL 33441 Re: Elevation Certificate for Peninsula II 3301 NE 183 Street, City of Aventura Dear Ms. Kanakis: SUSAN Got EB MAYOR COMMISSIONERS Av AUERBACH BOB DIAMOND TERI HOLZBERG BILLY JOEL MICHAELSIERN Luz URBAEZ W EINBERG ERIC M. SORom, ICMA -CM Cr1Y MANAGER This will confirm that the approved plans for this development show top of slab of the attached garage at 7'6" NGVD, a storage area for the building at 9'0" and the top of next floor containing the lobby and living units at 18'9 ". The elevation certificate submitted by Daniel C. Fortin, PSM dated June 22, 2007 indicates that the top of slab of the attached garage is +7.4, that the top of the bottom floor (storage level) is +9.5 NGVD and the top of the next higher floor which is the lobby and first living unit floor is +19.3. The lowest elevation of machinery or equipment servicing the building is +9.5. Base flood elevation according to the FIRM is +9.0. Your engineer, Hershell Gill P.E., has provided certification that the 10" concrete wall in the garage is adequate to resist flooding water loads up to the BFE without damage to the wall or its surrounding structure. The City will attach this certification to the elevation certificate. Yours truly i' Joanne Carr, AICP Planning Director I 1 � PHONE: 305 - 466.8900 • FAx: 305. 466.8939 www.citVofaventura.com J HERSHELL GILL CONSULTING ENGINEERS, INCco� No`9F`F�GFo 4GO I Ponce de Leon Blvd. • Suite 350 • Coral Gables • Plonda 33 14G ell" � 1� 1 Phone (305) GG7 -3G3 I • Fax (305) GG5 -9296 • E -Mail: hgill @bell5outh.net ee, > <k November 20, 2007 Mrs. Rebeca Kanakis BOCA DEVELOPERS, INC. 321 E. Hillsboro Blvd. Deerfield Beach, Florida 33441 Fax 954 - 363 -3900 Reference: PENINSULA II HGCE File: 389 Dear Rebeca: In regard to the Parking Garage Elevations at Peninsula Phase 2, the base flood elevation is +9 NGVD and the Parking Surface is +7' -6 resulting in a 1' -6 differential. There are openings in the Garage on the West (Entry-Exit) and South to Phase I. Because of these openings, I do not believe that FEMA Bulletin 1 -93 applies. Assuming for the moment that it does, much of the perimeter wall consists of a 10" concrete wall with #5 verticals at 12" O.C. each face. This is to certify that the 10" concrete wall is adequate to resist flooding water loads up to the BFE without damage to the wall or its surrounding structure. If you have any questions, please call. Sincer iy, Hershelk Gill, PE President I i 1 @1 9 �o @��jTti�G ,FcFi�FO eel, AVENTURA LAND HOLDING II, LTD. F`Op�F�T 321 East Hillsboro Blvd. Deerfield Beach, Florida 33441 November 26, 2007 Ms. Joanne Carr, AICP Director of Community Development City of Aventura 19200 West Country Club Drive Aventura, Florida 33180 Re: Parking Garage Elevation The Peninsula Condominium Dear Ms. Carr, Tel: (954) 418 -0208 Fax: (954) 418 -0207 Per you request, please find a letter from Hershell Gill Engineers stating we have adequate design to resist flooding water loads as required by FEN/IA. Any questions or concerns, please feel free to call me. Very l urs, Reba K na is Project Manager, Development 321 East Hillsboro Blvd. Deerfield Bch, FL 33441 rkanakis@bocadevelopers.com (954) 949 -3473 / Fax (954) 363 -3900 Enclosure Cc: Noe Martinez, Boca Developers Art Robinson, CFE File HERSHELL GILL CONSULTING ENGINEERS, INC. 4601 Ponce de Leon 51vd. • 5uite 350 • Coral Gables • Florida 33146 Phone (305) 667 -3G3 I • Fax (305) GG5 -9298 • E -Mad: h6jdl @bell5outh.net November 20, 2007 Mrs. Rebeca Kanakis BOCA DEVELOPERS, INC. 321 E. Hillsboro Blvd. Deerfield Beach, Florida 33441 Fax 954 -363 -3900 Reference: PENINSULA II HGCE File: 389 Dear Rebeca: In regard to the Parking Garage Elevations at Peninsula Phase 2, the base flood elevation is +9 NGVD and the Parking Surface is +T-6 resulting in a V -6 differential. There are openings in the Garage on the West (Entry-Exit) and South to Phase I. Because of these openings, I do not believe that FEMA Bulletin 1 -93 applies. Assuming for the moment that it does, much of the perimeter wall consists of a 10" concrete wall with #5 verticals at 12" O.C. each face. This is to certify that the 10" concrete wall is adequate to resist flooding water loads up to the BFE without damage to the wall or its surrounding structure. If you hAve any questions, please call. SincW ty,, F*sheliGllF'PEE.-- ° ^' Pt"'deig