Loading...
OptimaOPTIMA INTERNATIONAL BUILDING I U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE FEDERAL EMERGENCY MANAGEMENT AGENCY Notional Flood Msurnnce Program IMPORTANT: Follow the instructions on pages 1 -9. OMB No. 1660 -0008 Expiration Date: July 31, 2015 SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name OPTIMA INTERNATIONAL LLC Policy Number: A2. Bwldiin 5 reef ISCAYNE Bin A t., Unit, Suite, and/or Bldg. No.) or PO. Route and Box No. I Company NAIC Number: City AVENTURA State FL ZIP Code 33180 rvumoer, Legai uescnpnon, ecc.) of "Mao of the Town P.B. 12. Do 37 A4. Building Use (e.g., Residential, Non - Residential, Addition, Accessory, etc.) UOMMERCIAL A5. Latitude /Longitude: Lat. 2505828 "N Long. 80 °08'34 "NI Horizontal Datum: ❑ NAD 1927 ❑>< NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1R A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) 0 sq ft a) Square footage of attached garage 24.084 sq ft b) No. of permanent flood openings in the crawlspace or 0 b) Number of permanent flood openings in the attached garage enclosure(s) within 1.0 foot above adjacent grade within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in AB.b 0 sq in c) Total net area of flood openings in A9.b 0 sq in d) Engineered flood openings? ❑ Yes ENO d) Engineered flood openings? ❑ Yes E No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Bl. NAP Community Name & Community Number 62, Count Name BADE 63. State CITY OF AVENTURA 120676 MIAMI / FL B4. Map /Panel Number B5. Suffix B6. FIRM Index Date B7. FIRM Panel Effective/ B8. Rood Zone(s) B9. Base Flood Elevation(s) (Zone 0 N feet Revised Date b) Top of the next higher floor A0, use base flood depth) 12086C 0132 L 09/11/2009 09/11/2009 AE 1 6 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 39: ❑ AS Profile E FIRM ❑ Community Determined ❑ Other /Source: N/A Ell. indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other /Source: N A B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes E No Designation Date: / _ / _ ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl- Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* E Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR /A, AR /AE, AR /A1 -A30, AR /AH, AR /A0. Complete Items C2.a -h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: COUNTY BM# H-419 ELEV= 8.47' Vertical Datum: NGVD 1929 Indicate elevation datum used for the elevations in items a) through h) below. E NGVD 1929 ❑ NAVD 1988 ❑ Other /Source: N/A Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 9 0 N feet ❑ meters b) Top of the next higher floor 25 7 N feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A N feet ❑ meters d) Attached garage (top of slab) 8 0 N feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 8 . 2 N feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 7 3 E feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 8 . 1 E feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 8 . 1 N feet ❑ meters structural support SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to Interpret the data available. I understand that any false statement may be punishable by fine or Imprisonment under 18 U.S. Code, Section 1001. ❑x Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a D Check here if attachments. licensed land surveyor? N Yes ❑ No FEMA Form 086 -0 -33 (7/12) See reverse side for continuation. x/16( Replaces all previous editions. ELEVATION CERTIFICATE, page 2 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.D. Route and Box No. Policy Number: 01 State ZIP Code Company NAIC SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent /company, and (3) building owner. Comments Latitude & Longitude was obtained by our GPS STREET FINDER installed in our trucks and verified by the GOOGLE EARTH program. Field survey datum used is same as datum used for BFE in item B9, No conversion needed. Aga- Garage is attached parking garage with drainage in the floor. C2e- Electric room floor = 8.00' Signature IV C / 1 _ _ Date 02/04/2014 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items ES -E5. If the Certificate is intended to support a LOMA or LOMR -F request, complete Sections A, B,and C. For Items El -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is []feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6 -9 with permanent flood openings provided in Section A Items 8 and /or 9 (see pages 8 -9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or E4. Top of platform of machinery and /or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. ❑ below the HAG. ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A. 8, and E for Zone A (without a FEMA- issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name State aignamre Date Telephone ❑ Check here if attachments. SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B. C (or E), and G of this Elevation Certificate. Complete the applicable items) and sign below. Check the measurement used in Items G8 -G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA - issued or community- issued 8FE) or Zone AO. G3. ❑ The following information (Items G4 -G9) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued— 66. Date Certificate Of Compliance /Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum 01O.Communitv's design flood elevation: _ . _ ❑ feet ❑ meters Datum Local Community Name Telephone Signature Date ❑ Check here if attachments. FEMA Form 086 -0 -33 (7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 3 Building Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No FOR INSURANCE COMPANY USE Number: CITY State ZIP Code Company NAIC Number: AVENTURA FL 33180 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View "; and, if required, "Right Side View' and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. DATE TAKEN 02/04/14 DATE TAKEN 02/04/14 FEMA Form 086 -0 -33 (7/12) Replaces all previous editions.